Q-Tec Heat Pumps
- Available in Air-To-Air (QH) or Geothermal (QW) configurations
Designed to be installed inside the building structure for optimized aesthetics
"Whisper Quiet" Technology
Optional built-in Energy Recovery ventilator provides up to 450 cfm of outside air
Scroll Compressors
ARI Certified
ETL Listed US & Canada
Optional Ventilation & Controls Available
Limited Warranty Policy
QA Series Air Conditioner Info Link
QC Series Chilled Water Info Link
QH Series Air Source H/P Info Link
QW Series Water Source H/P Info Link
QA Series Q/Tec Air Conditioner Units |
| Nominal Cooling Capacities1 |
Ranges from 24,000 to 53,000 BTUH |
Nominal Heating Capacities |
Ranges from 24,000 to 53,000 BTUH |
| Electrical Options |
• 230/208-1-60
• 230/208-3-60
• 460-3-60 |
| Cooling Efficiency (EER)2 |
Ranges from 9.00 to 10.90 EER |
| Electric Heat Options |
Ranges from 0 KW to 15 KW |
| Ventilation Options |
• Barometric Fresh Air Damper
• Blank Off Plate
• Commercial Room Ventilator
• Economizer
• Energy Recovery Ventilator |
| Internal Control Options |
• High & Low Pressure Switch
• Compressor Time Delay Relay
• Low Ambient Control
• Alarm Relay |
| Specified Applications |
• Hot-Gas Reheat Dehumidification |
QC Series Q/Tec Chilled Water Units |
| Nominal Cooling Capacities1 |
Ranges from 13,300 to 49,300 BTUH |
Nominal Heating Capacities |
Optional Hot Water Coil |
| Electrical Options |
• 230/208-1-60
• 230/208-3-60 |
| Ventilation Options |
• Barometric Fresh Air Damper
• Blank Off Plate
• Commercial Room Ventilator
• Energy Recovery Ventilator |
QH Series II Q/Tec Air-To-Air Heat Pump Units |
| Nominal Cooling Capacities1 |
Ranges from 2 to 5 Tons |
Nominal Heating Capacities |
Ranges from 24,000 to 47,000 BTUH |
| Electrical Options |
• 230/208-1-60
• 230/208-3-60
• 460-3-60 |
| Cooling Efficiency (EER)2 |
Ranges from 9.00 to 10.9 EER |
| Heating Efficiency (COP)2 |
Range from 3.00 to 3.10 COP |
| Electric Heat Options |
Ranges from 0 KW to 15 KW |
| Ventilation Options |
• Barometric Fresh Air Damper
• Blank Off Plate
• Commercial Room Ventilator
• Energy Recovery Ventilator |
| Internal Control Options |
• High & Low Pressure Switch
• Compressor Time Delay Relay
• Low Ambient Control
• Outdoor Thermostat |
| Specified Applications |
• Hot-Gas Reheat Dehumidification
• Low Ampacity Circuit |
QW Series Q/Tec Geothermal Heat Pump Units |
| Nominal Cooling Capacities |
Ranges from 25,000 to 53,300 BTUH |
| Nominal Heating Capacities |
Ranges from 16,400 to 45,500 BTUH |
| Electrical Options |
• 230/208-1-60
• 230/208-3-60
• 460-3-60 |
| Cooling Efficiency (EER) |
Ranges from 13.4 to 16.6 EER |
| Heating Efficiency (COP) |
Ranges from 3.1 to 3.5 COP |
| Ventilation Options |
• Barometric Fresh Air Damper
• Blank Off Plate
• Commercial Room Ventilator
• Energy Recovery Ventilator |
| Internal Control Options |
• High & Low Pressure Switch
• Compressor Time Delay Relay |
- Capacity is certified in accordance with ARI Standard 390-2003.
|
|
|
|
 |